Smart Valve Positioner
Power Genex
Smart Valve Positioner
Positioner is smart performance with innovative and ever-strong coil module even under harsh working environments.
Power Genex Features :
- Detecting RA
- Ever-strong coil
- Low air consumption
- Allowing to be installed
- Quick auto-calibration
- Possible to test the actuator
- Providing a mounting bracket to meet
- Improved control of high-friction globe
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 80° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die-Cast |
Weight | 1,6 kg |
Power Genex
Smart Valve Positioner
Smart performance with flameproof enclosure and innovative and ever-strong coil module even under harsh working environments.
Power Genex Features :
- Ever-strong coil
- Low air consumption
- Available to use for single
- Installed on small actuators
- Temperature -30 ~ +75 celcius
- Providing error messages against
- Providing a mounting bracket to meet
- Improved control of high-friction globe
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 75° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die-Cast |
Weight | 2,8 kg |
Power Genex
Smart Valve Positioner
Smart performance with flameproof enclosure and innovative and ever-strong coil module even under harsh working environments.
Power Genex Features :
- Ever-strong coil
- Low air consumption
- Available to use for single
- Installed on small actuators
- Temperature -30 ~ +75 celcius
- Providing error messages against
- Providing a mounting bracket to meet
- Improved control of high-friction globe
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 75° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die-Cast |
Weight | 2,8 kg |
Power Genex
SS5 Fail Freeze Positioner
Perfect combination with reliable fail freeze function and smart performance with innovative durable coil drive.
Power Genex Features :
- Compact design
- Reliable fail freeze
- Any fixed signal under
- Temperature -30 ~ +80℃
- Low air consumption
- Eliminating an overshoot
- Available to use for single
- Installed on small actuators
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 80° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Powder Painted |
Weight | 1,6 kg |
Power Genex
SS Smart Positioner
Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program.
Power Genex Features :
- Easy operation
- Auto-calibration
- High resistance
- Low air consumption
- Full text graphical LCD
- High dynamic response
- Single and double acting
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Power Genex
SS Smart Positioner
Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program.
Power Genex Features :
- Easy operation
- Auto-calibration
- High resistance
- Low air consumption
- Full text graphical LCD
- High dynamic response
- Single and double acting
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Electro Pneumatic Positioner
Power Genex NEPL Linear Type
Electro Pneumatic Positioner
Robust valve control device giving a confidence in reliable performance and outstanding durability under harsh working environments.
Power Genex Features :
- Easy maintenance
- Reliable performance
- Outstanding durability
- 1/2 split range available
- Vibration resistant design
- Restricted pilot valve orifice
- Simple conversion to direct
- Stainless steel gauges standard
Other Power Genex Series :
- Power Genex EPL Linear Type
- Power Genex EPR Rotary Type
- Power Genex NEPR Rotary Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Power Genex NEPR Rotary
Electro Pneumatic Positioner
Certified for ATEX Eex md IIB T5 (05 ATEX 1076X) by NEMKO in conformance with EN 50014:1997, EN 50018:2000 and EN 50028:1987.
Power Genex Features :
- Simple SPAN
- Easy maintenance
- ZERO adjustments
- Precise calibration
- Split range available
- Vibration resistant design
- Stainless steel gauges standard
Other Power Genex Series :
- Power Genex EPL Linear Type
- Power Genex EPR Rotary Type
- Power Genex NEPL Linear Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Power Genex NEPR Rotary
Electro Pneumatic Positioner
Certified for ATEX Eex md IIB T5 (05 ATEX 1076X) by NEMKO in conformance with EN 50014:1997, EN 50018:2000 and EN 50028:1987.
Power Genex Features :
- Simple SPAN
- Easy maintenance
- ZERO adjustments
- Precise calibration
- Split range available
- Vibration resistant design
- Stainless steel gauges standard
Other Power Genex Series :
- Power Genex EPL Linear Type
- Power Genex EPR Rotary Type
- Power Genex NEPL Linear Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Power Genex EPL Linear Type
Electro Pneumatic Positioner
Certified for EMC (K1046/E04) in conformance with EN 61000-6-2:2001 and EN 61000-6-4:2001 by RWTUV.
Power Genex Features :
- Direct acting
- Reverse acting
- Easy maintenance
- Precise calibration
- Reliable performance
- Outstanding durability
- Vibration resistant design
- Stainless steel gauges standard
Other Power Genex Series :
- Power Genex EPR Rotary Type
- Power Genex NEPL Linear Type
- Power Genex NEPR Rotary Type
Detail Specification
Pressure Nominal | 7 bar (100 psi) |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 3,3 kg |
Power Genex EPR Rotary Type
Electro Pneumatic Positioner
Robust valve control device giving a confidence in reliable performance and outstanding durability under harsh working environments.
Power Genex Features :
- Simple SPAN
- High resistance
- ZERO adjustments
- Simple conversion
- Small actuators included
- Restricted pilot valve orifice kit
- Stainless steel gauges standard
- Simple conversion to direct acting
Other Power Genex Series :
- Power Genex EPL Linear Type
- Power Genex NEPL Linear Type
- Power Genex NEPR Rotary Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 3,5 kg |
Power Genex EPR Rotary Type
Electro Pneumatic Positioner
Robust valve control device giving a confidence in reliable performance and outstanding durability under harsh working environments.
Power Genex Features :
- Simple SPAN
- High resistance
- ZERO adjustments
- Simple conversion
- Small actuators included
- Restricted pilot valve orifice kit
- Stainless steel gauges standard
- Simple conversion to direct acting
Other Power Genex Series :
- Power Genex EPL Linear Type
- Power Genex NEPL Linear Type
- Power Genex NEPR Rotary Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 3,5 kg |
Pneumatic-Pneumatic Positioner
Power Genex NPPL Linear
Power Genex Pneumatic-Pneumatic Positioner NPPL
Robust valve control device giving a confidence in reliable performance and outstanding durability under harsh working environments.
Power Genex Features :
- Easy maintenance
- Reliable performance
- 1/2 split range available
- Vibration resistant design
- Restricted pilot valve orifice
- Simple conversion to direct
- Stainless steel gauges standard
Other Power Genex Series :
- Power Genex PPL Linear Type
- Power Genex PPR Rotary Type
- Power Genex NPPR Rotary Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Power Genex NPPR Rotary
Power Genex Pneumatic-Pneumatic Positioner NPPR
Precise calibration with simple SPAN and ZERO adjustments simple conversion to direct acting or reverse acting.
Power Genex Features :
- Easy maintenance
- Simple conversion
- Split range available
- Vibration resistant design
- Rugged aluminum housing
- Stainless steel gauges standard
- Restricted pilot valve orifice kit for small
Other Power Genex Series :
- Power Genex PPL Linear Type
- Power Genex PPR Rotary Type
- Power Genex NPPL Linear Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Power Genex NPPR Rotary
Power Genex Pneumatic-Pneumatic Positioner NPPR
Precise calibration with simple SPAN and ZERO adjustments simple conversion to direct acting or reverse acting.
Power Genex Features :
- Easy maintenance
- Simple conversion
- Split range available
- Vibration resistant design
- Rugged aluminum housing
- Stainless steel gauges standard
- Restricted pilot valve orifice kit for small
Other Power Genex Series :
- Power Genex PPL Linear Type
- Power Genex PPR Rotary Type
- Power Genex NPPL Linear Type
Detail Specification
Pressure Nominal | 1,4-7 bar (20-100 psi) |
Max Temp | -30° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,5 kg |
Power Genex PPL Linear Type
Power Genex Pneumatic-Pneumatic Positioner PPL
Robust valve control device giving a confidence in reliable performance and outstanding durability under harsh working environments.
Power Genex Features :
- Easy maintenance
- Reliable performance
- 1/2 split range available
- Vibration resistant design
- Restricted pilot valve orifice
- Simple conversion to direct
- Stainless steel gauges standard
Other Power Genex Series :
- Power Genex PPR Linear Type
- Power Genex NPPR Rotary Type
- Power Genex NPPL Linear Type
Detail Specification
Pressure Nominal | 7 bar (100 psi) |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,1 kg |
Power Genex PPR Rotary Type
Power Genex Pneumatic-Pneumatic Positioner PPR
Vibration resistant design Stainless steel gauges standard Restricted pilot valve orifice kit for small actuators included.
Power Genex Features :
- High temperature
- 2 X SPDT limit switch
- Visual dome indicator
- Split range available
- Vibration resistant design
- Stainless steel gauges standard
- Simple conversion to direct acting
Other Power Genex Series :
- Power Genex PPL Linear Type
- Power Genex NPPR Rotary Type
- Power Genex NPPL Linear Type
Detail Specification
Pressure Nominal | 7 bar (100 psi) |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,1 kg |
Power Genex PPR Rotary Type
Power Genex Pneumatic-Pneumatic Positioner PPR
Vibration resistant design Stainless steel gauges standard Restricted pilot valve orifice kit for small actuators included.
Power Genex Features :
- High temperature
- 2 X SPDT limit switch
- Visual dome indicator
- Split range available
- Vibration resistant design
- Stainless steel gauges standard
- Simple conversion to direct acting
Other Power Genex Series :
- Power Genex PPL Linear Type
- Power Genex NPPR Rotary Type
- Power Genex NPPL Linear Type
Detail Specification
Pressure Nominal | 7 bar (100 psi) |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 2,1 kg |
I/P Converter Positioner
Power Genex
I/P Converter IPC
Dynamic valve drive to convert 4~20㎃ current signal to pneumatic output pressure with state-of-the art piezoelectric technology.
Power Genex Features :
- Simple
- Easy to set
- high dynamic response
- Precise control performance
- Rugged aluminum die-cast housing
- Low air consumption due to piezo electric
Output Pressure :
- 0,2 – 1 Bar (3 – 15 psi)
- 0,2 – 3 Bar (3 – 45 psi)
- 0,4 – 2 Bar (6 – 30 psi)
Detail Specification
Pressure Nominal | Up to 5 micron |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/8 |
Body Material | Aluminium Die Cast |
Weight | 820 g |
Power Genex
I/P Converter IPC
Dynamic valve drive to convert 4~20㎃ current signal to pneumatic output pressure with state-of-the art piezoelectric technology.
Power Genex Features :
- Simple
- Easy to set
- high dynamic response
- Precise control performance
- Rugged aluminum die-cast housing
- Low air consumption due to
piezo electric
Output Pressure :
- 0,2 – 1 Bar (3 – 15 psi)
- 0,2 – 3 Bar (3 – 45 psi)
- 0,4 – 2 Bar (6 – 30 psi)
Detail Specification
Pressure Nominal | Up to 5 micron |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/8 |
Body Material | Aluminium Die Cast |
Weight | 820 g |
Cylinder Positioner
Power Genex
Cylinder Positioner
Positioner smart performance with innovative and ever-strong coil module even under harsh working environment.
Power Genex Features :
- Ever-strong coil
- Smart performance
- Low air consumption
- HART communication
- Profibus communication
- Automatically regardles
- Detecting RA (reverse acting)s
- Easy and quick auto-calibration
- 2x alarm limit or micro switch
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4 - 7 bar (20-100 psi) |
Max Temp | -30° C / 80° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 1,6 kg |
Power Genex
Cylinder Positioner
Positioner smart performance with innovative and ever-strong coil module even under harsh working environment.
Power Genex Features :
- Ever-strong coil
- Smart performance
- Low air consumption
- HART communication
- Profibus communication
- Automatically regardles
- Detecting RA (reverse acting)s
- Easy and quick auto-calibration
- 2x alarm limit or micro switch
Other Power Genex Series :
Detail Specification
Pressure Nominal | 1,4 - 7 bar (20-100 psi) |
Max Temp | -30° C / 80° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 1,6 kg |
Position Transmitter
Power Genex
Power Genex explosion proof position transmitter for reliable valve position feedback
Power Genex explosion proof position transmitter for reliable valve position feedback with 4-20㎃ output signal, rugged aluminum die-cast housing and optional 2 X SPDT limit switch or 2 X P&F proximity sensor NJ2-V3-N.
Limit Switches :
- N : None
- S : 2 x SPDT mechanical limit switch
- P : 2 x P&F proximity sensor NJ2-V3-N
Mounting Bracket :
- N : None
- L : IEC 60534-6-1 (for PTP-L)
- S : Special Bracket (on request)
- R : IEC 60534-6-2 (for PTP-R) VDI
Detail Specification
Power Supply Range | 12-30 VDC |
Max Temp | -30° C / 75° C |
Pneumatic Connections | PF (G) 1/2 or NPT 1/2 |
Body Material | Aluminium Die Cast |
Weight | 0,9 kg |
Power Genex
Power Genex explosion proof position transmitter for reliable valve position feedback
Power Genex explosion proof position transmitter for reliable valve position feedback with 4-20㎃ output signal, rugged aluminum die-cast housing and optional 2 X SPDT limit switch or 2 X P&F proximity sensor
NJ2-V3-N.
Limit Switches :
- N : None
- S : 2 x SPDT mechanical limit switch
- P : 2 x P&F proximity sensor NJ2-V3-N
Mounting Bracket :
- N : None
- L : IEC 60534-6-1 (for PTP-L)
- S : Special Bracket (on request)
- R : IEC 60534-6-2 (for PTP-R) VDI
Detail Specification
Power Supply Range | 12-30 VDC |
Max Temp | -30° C / 75° C |
Pneumatic Connections | PF (G) 1/2 or NPT 1/2 |
Body Material | Aluminium Die Cast |
Weight | 0,9 kg |
Selenoid Valve
Power Genex
Power Genex Solenoid Valve ESV-S Single Coil
Explosion proof solenoid valve for a confident control in rough working environments.
Power Genex Features :
- Explosion proof solenoid
- Flameproof, Ex d IIC T6/T5/T4
- Usable up to SIL 3 acc. IEC 61508
- Direct NAMUR mounting or screw
- Rugged aluminum die-cast housing
- Convertible from 5/2 way to 3/2 way
- Rotatable valve head for optimal mounting
- Dust ignition protection, Ex tb IIIC T85℃/T100℃/T135℃ Db
Other Power Genex Series :
Detail Specification
Nominal Pressure | 1,5 - 10 bar |
Max Temp | -30° C / 80° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Stainless Steel |
Weight | 2,3 kg |
Power Genex
Power Genex Solenoid Valve ESV-S Single Coil
Explosion proof solenoid valve for a confident control in rough working environments.
Power Genex Features :
- Explosion proof solenoid
- Flameproof, Ex d IIC T6/T5/T4
- Usable up to SIL 3 acc. IEC 61508
- Direct NAMUR mounting or screw
- Rugged aluminum die-cast housing
- Convertible from 5/2 way to 3/2 way
- Rotatable valve head for
optimal mounting - Dust ignition protection, Ex tb IIIC T85℃/T100℃/T135℃ Db
Other Power Genex Series :
Detail Specification
Nominal Pressure | 1,5 - 10 bar |
Max Temp | -30° C / 80° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Stainless Steel |
Weight | 2,3 kg |
Air Filter Regulator
Power Genex
Air Filter Regulator FR 10
Valve air unit essential to provide clean and dry supply air to valve positioners, solenoid valves and pneumatic actuators.
Power Genex Features :
- Provide clean
- High flow capacity
- Stable setting pressure
- Increase actuator speed
- High capacity with 5 micron filter
- Rugged aluminum die-cast housing
- Optional stainless steel 316 housing
- Self-relief function to balance output and setting pressures
Other Power Genex Series :
Detail Specification
Nominal Pressure | 0,4-0,8 bar (60-120 psi) |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Stainless Steel |
Weight | 1 kg |
Air Volume Booster
Power Genex
Air Volume Booster AVB-1000
Strong valve activator to increase actuator speed or decrease loss of supply air coming from a distance by supplying a larger flow capacity.
Power Genex Features :
- High flow capacity
- Larger flow capacity
- Increase actuator speed
- Rugged aluminum die-cast housing
- Optional 1/4 or 3/8, PT or NPT supply
- Provides a tight shut off to reduce a costly
- Delivers high air volume to actuator rapidly
- Tunes a unic response to eliminate an actuator overshoot or overdamping
Other Power Genex Series :
Detail Specification
Nominal Pressure | 10 bar (150 psi) |
Max Temp | -20° C / 120° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 0,56 kg |
Power Genex
Air Volume Booster AVB-1000
Strong valve activator to increase actuator speed or decrease loss of supply air coming from a distance by supplying a larger flow capacity.
Power Genex Features :
- High flow capacity
- Larger flow capacity
- Increase actuator speed
- Rugged aluminum die-cast housing
- Optional 1/4 or 3/8, PT or NPT supply
- Provides a tight shut off to
reduce a costly - Delivers high air volume to
actuator rapidly - Tunes a unic response to eliminate an actuator overshoot or overdamping
Other Power Genex Series :
Detail Specification
Nominal Pressure | 10 bar (150 psi) |
Max Temp | -20° C / 120° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 0,56 kg |
Position Monitor Valve
Power Genex
Position Monitor LSB-1000
Robust valve position monitor with a good recognizable beacon, various switches and feedback options. Other Series Valve Position Monitor LSB-3000 and Valve Position Monitor LSB-7000 a good recognizable.
Power Genex Features :
- Rugged aluminum die-cast housing
- Weatherproof to IP67 (optionally IP68)
- Various switches and sensors (available with Honeywell / P&F)
- NAMUR mounting shaft or fork lever shaft adjustable for a non-NAMUR
Power Genex Options :
- 2 x SPDT mechanical limit switch
- 4 x SPDT mechanical limit switch
- 2 x Hermetically-sealed proximity Sensors
Detail Specification
Nominal Pressure | 10 bar (150 psi) |
Max Temp | -40° C / 100° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 0,8 kg |
Lock-Up Valve
Power Genex
Lock Up Valve LU
Dependable safety valve to retain a set supply air pressure and guarantee a steady process control when a supply air is suddenly failed by accident and its pressure becomes lower than a set.
Power Genex Features :
- Easy operation
- Auto-calibration
- High resistance
- Low air consumption
- Guarantee a steady
- Full text graphical LCD
- High dynamic response
- Single and double acting
Power Genex Options :
- Sing / Double
- Rc 1/4, NPT 1/4
Detail Specification
Nominal Pressure | 10 bar (150 psi) |
Max Temp | -40° C / 100° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 0,8 kg |
Power Genex
Lock Up Valve LU
Dependable safety valve to retain a set supply air pressure and guarantee a steady process control when a supply air is suddenly failed by accident and its pressure becomes lower
than a set.
Power Genex Features :
- Easy operation
- Auto-calibration
- High resistance
- Low air consumption
- Guarantee a steady
- Full text graphical LCD
- High dynamic response
- Single and double acting
Power Genex Options :
- Sing / Double
- Rc 1/4, NPT 1/4
Detail Specification
Nominal Pressure | 10 bar (150 psi) |
Max Temp | -40° C / 100° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium Die Cast |
Weight | 0,8 kg |
Snap Acting Relay
Power Genex
Snap Acting Relay
Snap Acting Relay is the device which is usually used with an air tank, converts an air flow direction and moves the valve to the fail-safe position when the signal air pressure is lower than the set air pressure. Also, it has a fail-freeze function to help the valve stay-finish.
Power Genex Features :
- High flow capacity
- Stable setting pressure
- High capacity with 5 micron filter
- Rugged aluminum die-cast housing
- Optional stainless steel 316 housing
Power Genex Options :
- Stainless steel 316
- High temperature
- Low temperature
Detail Specification
Nominal Pressure | 10 bar (150 psi) |
Max Temp | -20° C / 70° C |
Pneumatic Connections | PT (RC) 1/4 or NPT 1/4 |
Body Material | Aluminium |
Weight | 1,2 kg |